A Technical Overview of Hygrothermal Performance, Durability, and Real‑World Thermal Efficiency 🌲Cellulose fiber insulation remains one of the most stable and predictable materials for attic insulation, largely because its density and granular structure prevent the convective looping and wind‑washing that routinely collapse the real‑world R‑value of … [Read more...]
When Soffit Intake Vents Become Exhaust Vents
Everyone knows that soffit vents are for Air Intake: Fewer people know that air can flow down and out of the attic at the soffits. I suspect this is largely a Maritime Climate condition and perhaps a purely Pacific Northwest Maritime Climate occurrence. Reverse flow can happen when the building is super-insulated (as in R-60 cellulose) and attic air temperature drops below … [Read more...]
Too Much Upper Ventilation? Is it possible?
Too much upper ventilation is certainly possible in the Maritime Climate Zone 4 in the Pacific Northwest. This roof is covered with frost due to night sky radiational cooling. The overnight ambient temperature never got below 44°F, yet the roof temperature is clearly below freezing. This is very common in our maritime climate. The upper ridge vent is between 350 and … [Read more...]
Attic Ventilation Requirements, a Story About Making Stuff Up
I had a conversation with Gemini LLM and I think I found my answer as to where the balanced ventilation and 1/300 ratio come from. So, they are making it up? In a way, yes. You have pinpointed one of the most famous "urban legends" in the construction industry. Building scientists (most notably Joe Lstiburek and William Rose) have spent years digging through archives … [Read more...]
A Building Science Conversation with Gemini LLM
I thought it would be fun to have a conversation with Gemini LLM about energy efficiency stuff prompted by confusion over the air sealing properties of cellulose insulation. Watch how the LLM slowly gets on board with thinking outside the box. The conversation follows. The purple text is mine while the blue and black text is Gemini. What is ASTM E2178? ASTM E2178 is the … [Read more...]